TY - JOUR
T1 - 2-Mercaptoethylamine as a masking agent for the complexometric determination of palladium(II) in catalysts, alloys and complexes
AU - Shetty, Prakash
AU - Shetty, A. Nityananda
PY - 2008/1/1
Y1 - 2008/1/1
N2 - A simple, rapid and accurate complexometric method for the determination of palladium in the presence of other metal ions is described, based on the selective masking ability of 2-mercaptoethylamine (MEA) towards Pd(II). Palladium(II) along with other associated metal ions present in a given sample solution is first complexed with an excess of EDTA and the surplus EDTA is titrated with zinc sulphate solution at pH 5-6 (acetic acid-sodium acetate buffer) using xylenol as indicator. A known excess of 0.2% aqueous solution of MEA is then added to displace EDTA from Pd(II)-EDTA complex and swirled well. The released EDTA is again titrated with zinc sulphate solution as before. The method works well in the range 2-20 mg of palladium(II) with the relative error ± 0.27 and the relative standard deviation < 0.35%. The effect of the presence of various diverse ions on the accuracy of the results has been studied. The method has been satisfactorily applied for the determination of palladium in catalysts, alloys and complexes.
AB - A simple, rapid and accurate complexometric method for the determination of palladium in the presence of other metal ions is described, based on the selective masking ability of 2-mercaptoethylamine (MEA) towards Pd(II). Palladium(II) along with other associated metal ions present in a given sample solution is first complexed with an excess of EDTA and the surplus EDTA is titrated with zinc sulphate solution at pH 5-6 (acetic acid-sodium acetate buffer) using xylenol as indicator. A known excess of 0.2% aqueous solution of MEA is then added to displace EDTA from Pd(II)-EDTA complex and swirled well. The released EDTA is again titrated with zinc sulphate solution as before. The method works well in the range 2-20 mg of palladium(II) with the relative error ± 0.27 and the relative standard deviation < 0.35%. The effect of the presence of various diverse ions on the accuracy of the results has been studied. The method has been satisfactorily applied for the determination of palladium in catalysts, alloys and complexes.
UR - http://www.scopus.com/inward/record.url?scp=54949115783&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=54949115783&partnerID=8YFLogxK
U2 - 10.4067/S0717-97072008000300013
DO - 10.4067/S0717-97072008000300013
M3 - Article
AN - SCOPUS:54949115783
SN - 0717-9324
VL - 53
SP - 1611
EP - 1614
JO - Journal of the Chilean Chemical Society
JF - Journal of the Chilean Chemical Society
IS - 3
ER -