TY - JOUR
T1 - A Comparison of the Visual Field Parameters of SITA Faster and SITA Standard Strategies in Glaucoma
AU - Lavanya, Raghavan
AU - Riyazuddin, Mohammed
AU - Dasari, Srilakshmi
AU - Puttaiah, Narendra K.
AU - Venugopal, Jayasree P.
AU - Pradhan, Zia S.
AU - Devi, Sathi
AU - Sreenivasaiah, Shruthi
AU - Ganeshrao, Shonraj B.
AU - Rao, Harsha L.
N1 - Publisher Copyright:
Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2020/9/1
Y1 - 2020/9/1
N2 - Purpose:To compare the visual field (VF) parameters of the new Swedish Interactive Thresholding Algorithm (SITA), SITA Faster (SFR) with that of SITA Standard (SS) on the Humphrey Field Analyzer.Methods:Ninety-seven eyes of 97 subjects (63 glaucoma, 26 glaucoma suspects, and 8 normal eyes) underwent VF examination with SFR and SS strategies on the same day in random order. Agreement in VF parameters between SFR and SS strategies was assessed by Bland and Altman plots. In addition, some subjects underwent a second VF examination with SFR strategy to evaluate its test-retest variability.Results:The median test duration of SS strategy was 6 minutes 14 seconds, whereas SFR was 2 minutes 49 seconds (55% shorter, P<0.001). Median mean deviation (-7.3 vs. -7.6 dB, P=0.73) and VF index (88 vs. 88%, P=0.32) were similar between the 2 strategies, whereas pattern standard deviation was significantly higher (4.8 vs. 4.7 dB, P=0.01) with SS strategy. Overall average threshold sensitivity and Garway-Heath sector-wise threshold sensitivities were similar between the 2 strategies except for the nasal sector where SFR strategy had higher sensitivity (26 vs. 25 dB, P=0.02). Bland-Altman plots showed the mean difference in all VF parameters between the SS and SFR strategies were small (ranging from -1.0 dB for the nasal sector to -0.01 dB for superotemporal sector sensitivity). The test-retest variability of VF parameters with SFR strategy was low.Conclusions:VF parameters with SFR showed good agreement with that of SS strategy. This, combined with low test-retest variability, suggests that SFR can be considered for diagnosis and monitoring of glaucoma.
AB - Purpose:To compare the visual field (VF) parameters of the new Swedish Interactive Thresholding Algorithm (SITA), SITA Faster (SFR) with that of SITA Standard (SS) on the Humphrey Field Analyzer.Methods:Ninety-seven eyes of 97 subjects (63 glaucoma, 26 glaucoma suspects, and 8 normal eyes) underwent VF examination with SFR and SS strategies on the same day in random order. Agreement in VF parameters between SFR and SS strategies was assessed by Bland and Altman plots. In addition, some subjects underwent a second VF examination with SFR strategy to evaluate its test-retest variability.Results:The median test duration of SS strategy was 6 minutes 14 seconds, whereas SFR was 2 minutes 49 seconds (55% shorter, P<0.001). Median mean deviation (-7.3 vs. -7.6 dB, P=0.73) and VF index (88 vs. 88%, P=0.32) were similar between the 2 strategies, whereas pattern standard deviation was significantly higher (4.8 vs. 4.7 dB, P=0.01) with SS strategy. Overall average threshold sensitivity and Garway-Heath sector-wise threshold sensitivities were similar between the 2 strategies except for the nasal sector where SFR strategy had higher sensitivity (26 vs. 25 dB, P=0.02). Bland-Altman plots showed the mean difference in all VF parameters between the SS and SFR strategies were small (ranging from -1.0 dB for the nasal sector to -0.01 dB for superotemporal sector sensitivity). The test-retest variability of VF parameters with SFR strategy was low.Conclusions:VF parameters with SFR showed good agreement with that of SS strategy. This, combined with low test-retest variability, suggests that SFR can be considered for diagnosis and monitoring of glaucoma.
UR - http://www.scopus.com/inward/record.url?scp=85085954404&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85085954404&partnerID=8YFLogxK
U2 - 10.1097/IJG.0000000000001551
DO - 10.1097/IJG.0000000000001551
M3 - Article
C2 - 32459685
AN - SCOPUS:85085954404
SN - 1057-0829
VL - 29
SP - 783
EP - 788
JO - Journal of Glaucoma
JF - Journal of Glaucoma
IS - 9
ER -