Abstract

Aim: The aim of this study is to compare the radiation dose in present Onco protocol and low dose protocol for head and neck and pelvic phantom in radiotherapy planning computed tomography and to establish diagnostic reference level. Objective: We conducted a following study to compare the radiation dose in standard protocol and the scan with different set of parameters. Methodology: A experimental phantom study was performed in CATPHAN 503 measuring 20cm to investigate the optimization of radiation dose for CT head and neck and pelvis by using different parameters available in CT control console. Result: The result showed significant change in radiation dose in terms of CTDIvol, DLP and effective with different combination of kVp and mAs without compromising image quality.

Original languageEnglish
Pages (from-to)258-262
Number of pages5
JournalIndian Journal of Public Health Research and Development
Volume10
Issue number5
DOIs
Publication statusPublished - 05-2019

All Science Journal Classification (ASJC) codes

  • Public Health, Environmental and Occupational Health

Fingerprint

Dive into the research topics of 'A pilot study on comparison of radiation dose in present onco protocol and varied parameters protocol for head and neck and pelvic phantom in computed tomography'. Together they form a unique fingerprint.