TY - JOUR
T1 - ACL reconstruction using femoral Rigid-fix and tibial Bio-intrafix devices
AU - Singh, Rahul
AU - Tripathy, Sujit Kumar
AU - Naik, Monappa A.
AU - Sujir, Premjit
AU - Rao, Sharath K.
PY - 2017/7/1
Y1 - 2017/7/1
N2 - Objectives The objective of this study is to report the clinical and functional outcomes of Hamstring graft ACL reconstruction fixed with femoral Rigid-fix and tibial Bio-intrafix devices. Methods In a prospective study, the clinical (Lysholm score) and functional outcomes (International Knee Documentation Committee, IKDC) of 44 patients who underwent autologus hamstring graft ACL reconstruction using femoral Rigid-fix and tibial Bio-intrafix devices, were evaluated at the end of one year. Joint laxity was assessed with KT-1000 arthrometer (MEDmetric, San Diego, CA). Results None of the patients complained of instability, joint swelling or severe pain in the postoperative period. The IKDC score improved from 66.62 + 5.36 to 92.36 + 5.30 (P < 0.001). Lysholm scores in the preoperative and follow up period were 68.28 + 5.54 and 93.87 + 4.75 respectively; the improvement was statistically significant with P value < 0.001. Similarly, the mean anterior translation of tibia improved from 7.45 mm in the preoperative period to 3.89 mm after one year of ACL reconstruction. Associated meniscus injury didn't have significant impact on the overall outcome. No intraoperative or postoperative complications were documented. Conclusion Hamstring graft fixation using femoral Rigid-fix and tibial Bio-intrafix devices provide secure graft fixation and allows aggressive rehabilitation. The clinical and functional outcome of this hybrid fixation technique is rewarding.
AB - Objectives The objective of this study is to report the clinical and functional outcomes of Hamstring graft ACL reconstruction fixed with femoral Rigid-fix and tibial Bio-intrafix devices. Methods In a prospective study, the clinical (Lysholm score) and functional outcomes (International Knee Documentation Committee, IKDC) of 44 patients who underwent autologus hamstring graft ACL reconstruction using femoral Rigid-fix and tibial Bio-intrafix devices, were evaluated at the end of one year. Joint laxity was assessed with KT-1000 arthrometer (MEDmetric, San Diego, CA). Results None of the patients complained of instability, joint swelling or severe pain in the postoperative period. The IKDC score improved from 66.62 + 5.36 to 92.36 + 5.30 (P < 0.001). Lysholm scores in the preoperative and follow up period were 68.28 + 5.54 and 93.87 + 4.75 respectively; the improvement was statistically significant with P value < 0.001. Similarly, the mean anterior translation of tibia improved from 7.45 mm in the preoperative period to 3.89 mm after one year of ACL reconstruction. Associated meniscus injury didn't have significant impact on the overall outcome. No intraoperative or postoperative complications were documented. Conclusion Hamstring graft fixation using femoral Rigid-fix and tibial Bio-intrafix devices provide secure graft fixation and allows aggressive rehabilitation. The clinical and functional outcome of this hybrid fixation technique is rewarding.
UR - http://www.scopus.com/inward/record.url?scp=85021977282&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85021977282&partnerID=8YFLogxK
U2 - 10.1016/j.jcot.2017.06.021
DO - 10.1016/j.jcot.2017.06.021
M3 - Article
AN - SCOPUS:85021977282
SN - 0976-5662
VL - 8
SP - 254
EP - 258
JO - Journal of Clinical Orthopaedics and Trauma
JF - Journal of Clinical Orthopaedics and Trauma
IS - 3
ER -