TY - GEN
T1 - AERODYNAMIC PERFORMANCE EVALUATION of AXIAL FLOW FAN USING NUMERICAL TECHNIQUES
AU - Raghuvaran, D.
AU - Shenoy, Satvik
AU - Srinivas, G.
N1 - Publisher Copyright:
© 2021 by ASME.
PY - 2021
Y1 - 2021
N2 - Axial flow fans (AFF) are extensively used in various industrial sectors, usually with flows of low resistance and high mass flow rates. The blades, the hub and the shroud are the three major parts of an AFF. Various kinds of optimisation can be implemented to improve the performance of an AFF. The most common type is found to be geometric optimisation including variation in number of blades, modification in hub and shroud radius, change in angle of attack and blade twist, etc. After validation of simulation model and carrying out a grid independence test, parametric analysis was done on an 11- bladed AFF with a shroud of uniform radius using ANSYS Fluent. The rotational speed of the fan and the velocity at fan inlet were the primary variables of the study. The variation in outlet mass flow rate and total pressure was studied for both compressible and incompressible ambient flows. Relation of mass flow rate and total pressure with inlet velocity is observed to be linear and exponential respectively. On the other hand, mass flow rate and total pressure have nearly linear relationship with rotational speed. A comparison of several different axial flow tracks with the baseline case fills one of the research gaps.
AB - Axial flow fans (AFF) are extensively used in various industrial sectors, usually with flows of low resistance and high mass flow rates. The blades, the hub and the shroud are the three major parts of an AFF. Various kinds of optimisation can be implemented to improve the performance of an AFF. The most common type is found to be geometric optimisation including variation in number of blades, modification in hub and shroud radius, change in angle of attack and blade twist, etc. After validation of simulation model and carrying out a grid independence test, parametric analysis was done on an 11- bladed AFF with a shroud of uniform radius using ANSYS Fluent. The rotational speed of the fan and the velocity at fan inlet were the primary variables of the study. The variation in outlet mass flow rate and total pressure was studied for both compressible and incompressible ambient flows. Relation of mass flow rate and total pressure with inlet velocity is observed to be linear and exponential respectively. On the other hand, mass flow rate and total pressure have nearly linear relationship with rotational speed. A comparison of several different axial flow tracks with the baseline case fills one of the research gaps.
UR - http://www.scopus.com/inward/record.url?scp=85122340807&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85122340807&partnerID=8YFLogxK
U2 - 10.1115/GTINDIA2021-76443
DO - 10.1115/GTINDIA2021-76443
M3 - Conference contribution
AN - SCOPUS:85122340807
T3 - Proceedings of ASME 2021 Gas Turbine India Conference, GTINDIA 2021
BT - Proceedings of ASME 2021 Gas Turbine India Conference, GTINDIA 2021
PB - American Society of Mechanical Engineers(ASME)
T2 - ASME 2021 Gas Turbine India Conference, GTINDIA 2021
Y2 - 2 December 2021 through 3 December 2021