TY - JOUR
T1 - Agreement between two Goldmann type applanation tonometers
AU - George, Ronnie
AU - Arvind, Hemamalini
AU - Baskaran, M.
AU - Ramesh, S.
AU - Raju, Prema
AU - Vijaya, Lingam
PY - 2008/11/1
Y1 - 2008/11/1
N2 - The aim of the study was to assess agreement between two commercially available applanation tonometers for the measurement of intraocular pressure (IOP). Forty subjects underwent IOP measurement on two accurately calibrated Goldmann type applanation tonometers (Zeiss AT 030 (GATZ) and Inami L-5110(GATI)). The order of examination was randomized and observers were masked to the IOP recorded. The mean of two consecutive readings, from a randomly selected eye for each subject, was used for analysis. Agreement was assessed using the Altman and Bland plot. The mean (SD) IOP readings on GATZ was 15.32 (±6.80) mm Hg and on GATI was 13.52 (±5.65) mm Hg (p < 0.001, 95% CI of the difference: -2.48 to -1.11). The 95% limits of agreement on the Altman and Bland plot were:-2.47 to 6.16 mm Hg). There was significant inter-instrument variability between the two accurately calibrated Goldmann type applanation tonometers studied.
AB - The aim of the study was to assess agreement between two commercially available applanation tonometers for the measurement of intraocular pressure (IOP). Forty subjects underwent IOP measurement on two accurately calibrated Goldmann type applanation tonometers (Zeiss AT 030 (GATZ) and Inami L-5110(GATI)). The order of examination was randomized and observers were masked to the IOP recorded. The mean of two consecutive readings, from a randomly selected eye for each subject, was used for analysis. Agreement was assessed using the Altman and Bland plot. The mean (SD) IOP readings on GATZ was 15.32 (±6.80) mm Hg and on GATI was 13.52 (±5.65) mm Hg (p < 0.001, 95% CI of the difference: -2.48 to -1.11). The 95% limits of agreement on the Altman and Bland plot were:-2.47 to 6.16 mm Hg). There was significant inter-instrument variability between the two accurately calibrated Goldmann type applanation tonometers studied.
UR - http://www.scopus.com/inward/record.url?scp=54349120851&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=54349120851&partnerID=8YFLogxK
U2 - 10.4103/0301-4738.43381
DO - 10.4103/0301-4738.43381
M3 - Article
C2 - 18974529
AN - SCOPUS:54349120851
SN - 0301-4738
VL - 56
SP - 516
EP - 517
JO - Journal of the All-India Ophthalmological Society
JF - Journal of the All-India Ophthalmological Society
IS - 6
ER -