N2 - Design of an intelligent level measurement technique by Capacitance Level Sensor (CLS) using an Optimized Artificial Neural Network (OANN) is discussed in this paper. The objectives of the present work are (i) to extend the linearity range of measurement to 100% of the full scale, (ii) to make the measurement technique adaptive of variation in permittivity of liquid, liquid temperature, and to achieve objectives (i) and (ii) using an optimized neural network. An optimized ANN is considered by comparing various algorithms, transfer functions of neuron, and number of hidden layers based on minimum mean square error (MSE). The output of CLS is capacitance. A data conversion unit is used to convert it to voltage. A suitable optimized ANN is added, in place of conventional calibration circuit, in cascade to data conversion unit. The proposed technique provides linear relationship of the overall system over the full input range and makes it adaptive of variation in liquid permittivity and/or temperature. When an unknown level is tested with an arbitrary liquid permittivity, and temperature, the proposed technique has measured the level correctly. Results show that the proposed scheme has fulfilled the objectives.
AB - Design of an intelligent level measurement technique by Capacitance Level Sensor (CLS) using an Optimized Artificial Neural Network (OANN) is discussed in this paper. The objectives of the present work are (i) to extend the linearity range of measurement to 100% of the full scale, (ii) to make the measurement technique adaptive of variation in permittivity of liquid, liquid temperature, and to achieve objectives (i) and (ii) using an optimized neural network. An optimized ANN is considered by comparing various algorithms, transfer functions of neuron, and number of hidden layers based on minimum mean square error (MSE). The output of CLS is capacitance. A data conversion unit is used to convert it to voltage. A suitable optimized ANN is added, in place of conventional calibration circuit, in cascade to data conversion unit. The proposed technique provides linear relationship of the overall system over the full input range and makes it adaptive of variation in liquid permittivity and/or temperature. When an unknown level is tested with an arbitrary liquid permittivity, and temperature, the proposed technique has measured the level correctly. Results show that the proposed scheme has fulfilled the objectives.
UR - https://www.scopus.com/pages/publications/84875930881
UR - https://www.scopus.com/inward/citedby.url?scp=84875930881&partnerID=8YFLogxK
U2 - 10.1117/12.2010412
DO - 10.1117/12.2010412
M3 - Conference contribution
AN - SCOPUS:84875930881
SN - 9780819495570
VL - 8760
T3 - Proceedings of SPIE - The International Society for Optical Engineering
BT - International Conference on Communication and Electronics System Design
T2 - International Conference on Communication and Electronics System Design, ICCESD 2013
Y2 - 28 January 2013 through 30 January 2013
ER -