TY - JOUR
T1 - Comparative Evaluation of Fracture Resistance of Various Core Buildup Materials on Endodontically Treated Teeth
T2 - An In Vitro Study
AU - Kumbaiah, Greeshma
AU - Hegde, Veena
AU - Ginjupalli, Kishore
AU - Sulaya, Kavishma
AU - Jayaprakash, K.
N1 - Publisher Copyright:
© 2022 Journal of International Oral Health | Published by Wolters Kluwer - Medknow.
PY - 2022/11
Y1 - 2022/11
N2 - Aim: The present study aimed to evaluate and compare the fracture resistance of four different core build-up materials on endodontically treated teeth. Materials and Methods: In this in vitro study, sample size estimation was done using G*power software (version 3.1.9.2), an effect size of 0.66 was obtained at 95% confidence interval. 48 Teeth samples were decoronated 2 mm above the Cementoenamel junction. Root canal treatment done, followed by preparation of post space and fiberglass posts of 10 mm length was cemented with resin cement into the root canal and 4 mm above the prepared tooth. All the samples were randomly divided into 4 groups of 12 samples for four different core build up materials. All teeth were restored with a Nickel chromium crown of standard dimensions and cemented with glass ionomer cement. Fracture resistance measured by applying the load at an angle of 135° to the long axis of the tooth at a crosshead speed of 0.05 mm/min until failure. Analysis was performed using KRUSKAL-WALLIS to compare mean values and standard deviation of fracture resistance, followed by post – hoc MANN WHITNEY test for assessing the significant difference of fracture resistance between the four groups. Results: Resistance to fracture was greater in Luxacore Z group followed by Vitremer, Denfil and Filtek. However, no statistically significant differences in the fracture resistance were observed among the groups. Conclusion: The results indicate that Luxacore Z core build-up material exhibits superior fracture resistance. Resin modified glass ionomer cement had fracture resistance comparable to Luxacore.
AB - Aim: The present study aimed to evaluate and compare the fracture resistance of four different core build-up materials on endodontically treated teeth. Materials and Methods: In this in vitro study, sample size estimation was done using G*power software (version 3.1.9.2), an effect size of 0.66 was obtained at 95% confidence interval. 48 Teeth samples were decoronated 2 mm above the Cementoenamel junction. Root canal treatment done, followed by preparation of post space and fiberglass posts of 10 mm length was cemented with resin cement into the root canal and 4 mm above the prepared tooth. All the samples were randomly divided into 4 groups of 12 samples for four different core build up materials. All teeth were restored with a Nickel chromium crown of standard dimensions and cemented with glass ionomer cement. Fracture resistance measured by applying the load at an angle of 135° to the long axis of the tooth at a crosshead speed of 0.05 mm/min until failure. Analysis was performed using KRUSKAL-WALLIS to compare mean values and standard deviation of fracture resistance, followed by post – hoc MANN WHITNEY test for assessing the significant difference of fracture resistance between the four groups. Results: Resistance to fracture was greater in Luxacore Z group followed by Vitremer, Denfil and Filtek. However, no statistically significant differences in the fracture resistance were observed among the groups. Conclusion: The results indicate that Luxacore Z core build-up material exhibits superior fracture resistance. Resin modified glass ionomer cement had fracture resistance comparable to Luxacore.
UR - http://www.scopus.com/inward/record.url?scp=85146506348&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85146506348&partnerID=8YFLogxK
U2 - 10.4103/jioh.jioh_288_21
DO - 10.4103/jioh.jioh_288_21
M3 - Article
AN - SCOPUS:85146506348
SN - 0976-7428
VL - 14
SP - 597
EP - 602
JO - Journal of International Oral Health
JF - Journal of International Oral Health
IS - 6
ER -