TY - JOUR
T1 - Comparative Evaluation of Surface Defects In Single File Rotary Systems Before and After Instrumentation In Curved Root Canals
AU - Purayil, T. P.
AU - Ballal, N. V.
AU - Ginjupalli, K.
PY - 2018/8/30
Y1 - 2018/8/30
N2 - This study aims to evaluate the surface defects and efficiency of two single file rotary systems with different surface treatments in curved root canal instrumentation. A total of 160 root canals were randomly divided into two groups and were subjected to root canal instrumentation with electropolished surface rotary file (Group 1) and with EDM surface treated rotary file (Group 2). All the files were then subjected to SEM analysis to evaluate the surface defects prior to the root canal instrumentation,after 5 uses and 8 uses inside the root canal. From the scanning electron microscopic images, the surface defects as observed were scored and were statistically analyzed. SEM analysis of both the single file systems revealed significantly varying surface defects. Rotary file with electropolishing appeared to be more resistant to deformation compared to the rotary file with EDM treatment after instrumentation of five canals. Hence it can be concluded that electropolished file can be safely instrumented for five times compared to EDM processed files in curved root canals.
AB - This study aims to evaluate the surface defects and efficiency of two single file rotary systems with different surface treatments in curved root canal instrumentation. A total of 160 root canals were randomly divided into two groups and were subjected to root canal instrumentation with electropolished surface rotary file (Group 1) and with EDM surface treated rotary file (Group 2). All the files were then subjected to SEM analysis to evaluate the surface defects prior to the root canal instrumentation,after 5 uses and 8 uses inside the root canal. From the scanning electron microscopic images, the surface defects as observed were scored and were statistically analyzed. SEM analysis of both the single file systems revealed significantly varying surface defects. Rotary file with electropolishing appeared to be more resistant to deformation compared to the rotary file with EDM treatment after instrumentation of five canals. Hence it can be concluded that electropolished file can be safely instrumented for five times compared to EDM processed files in curved root canals.
UR - http://www.scopus.com/inward/record.url?scp=85055615218&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85055615218&partnerID=8YFLogxK
U2 - 10.1922/EJPRD_01714Purayil06
DO - 10.1922/EJPRD_01714Purayil06
M3 - Article
C2 - 30152957
AN - SCOPUS:85055615218
SN - 0965-7452
VL - 26
SP - 130
EP - 135
JO - The European journal of prosthodontics and restorative dentistry
JF - The European journal of prosthodontics and restorative dentistry
IS - 3
ER -