T1 - Computational fluid dynamics study of respiratory mask for neonatal resuscitation
AU - Corda, John Valerian
AU - Shenoy, B. Satish
AU - Ahmad, Kamarul Arifin
AU - Lewis, Leslie
AU - Prakashini, K.
AU - Rao, Anoop
AU - Khader, S. M.Abdul
AU - Zuber, Mohammad
N1 - Publisher Copyright:
© 2024 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.
PY - 2024
Y1 - 2024
N2 - Face cups form a vital component of breathing, assisting with devices that aid in artificial breathing for neonates. This study aims to evaluate the flow parameters in the nasal cavity for two different types of face cups. The neonatal nasal cavity model was developed from CT scans using MIMICS 21.0. Two face cups, one hemispherical and the other anatomical shaped cups are developed around the nasal cavity and the airflow is simulated using ANSYS 2021 R2. Results are compared with a nasal-only model. At the nasal valve region, the highest velocity is seen for the nasal-only model which is 16.3% higher than that of the hemispherical face cup and 15.2% superior to the anatomical-shaped face cup. In addition, the decrease in pressure across the nasal-only model is 7.4 and 6.6% below that of the hemispherical cup and anatomical cup masks. The nasal resistance values across the nasal cavity are the lowest for the nasal-only model, 7.7 and 6.7% lower respectively than the hemispherical and anatomical-shaped cups. There were very minor changes in the flow parameters such as velocity, pressure and wall shear stress when comparing the hemispherical and anatomic-shaped masks for the airflow inside the nasal cavity.
AB - Face cups form a vital component of breathing, assisting with devices that aid in artificial breathing for neonates. This study aims to evaluate the flow parameters in the nasal cavity for two different types of face cups. The neonatal nasal cavity model was developed from CT scans using MIMICS 21.0. Two face cups, one hemispherical and the other anatomical shaped cups are developed around the nasal cavity and the airflow is simulated using ANSYS 2021 R2. Results are compared with a nasal-only model. At the nasal valve region, the highest velocity is seen for the nasal-only model which is 16.3% higher than that of the hemispherical face cup and 15.2% superior to the anatomical-shaped face cup. In addition, the decrease in pressure across the nasal-only model is 7.4 and 6.6% below that of the hemispherical cup and anatomical cup masks. The nasal resistance values across the nasal cavity are the lowest for the nasal-only model, 7.7 and 6.7% lower respectively than the hemispherical and anatomical-shaped cups. There were very minor changes in the flow parameters such as velocity, pressure and wall shear stress when comparing the hemispherical and anatomic-shaped masks for the airflow inside the nasal cavity.
UR - http://www.scopus.com/inward/record.url?scp=85196101715&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85196101715&partnerID=8YFLogxK
U2 - 10.1080/10255842.2024.2367120
DO - 10.1080/10255842.2024.2367120
M3 - Article
AN - SCOPUS:85196101715
SN - 1025-5842
JO - Computer Methods in Biomechanics and Biomedical Engineering
JF - Computer Methods in Biomechanics and Biomedical Engineering
ER -