Abstract
The paper details the design and simulation of a solar powered vapour compression refrigeration system. The effect of a phase change material, in this case ice, on a vapour compression refrigeration system powered by solar panels is discussed. The battery and solar panels were sized to allow the system to function as an autonomous unit for a minimum of 12 hours. It was concluded that the presence of a phase change material in the refrigeration system caused a considerable increase in both the on and off time of the compressor. The ratio by which the on time increased was greater than the ratio by which the off time was increased. There was a 219% increase in the on time, a 139% increase in the compressor off time and a 3.5% increase in compressor work accompanied by a 5.5% reduction in COP. Thus, under conditions where there is enough load in the system to cause the initial on and off times of the compressor to be comparable, the presence of a phase change material may result in a greater on period than an off period for the compressor.
| Original language | English |
|---|---|
| Article number | 04002 |
| Journal | MATEC Web of Conferences |
| Volume | 144 |
| DOIs | |
| Publication status | Published - 09-01-2018 |
| Event | 2017 International Conference on Research in Mechanical Engineering Sciences, RiMES 2017 - Manipal, Karnataka, India Duration: 21-12-2017 → 23-12-2017 |
All Science Journal Classification (ASJC) codes
- General Chemistry
- General Materials Science
- General Engineering