Abstract
A sensitive and selective high performance liquid chromatographic (HPLC) method was developed and validated for quantification of lacosamide in rat plasma. A liquid-liquid extraction procedure was optimized to extract lacosamide from rat plasma. Chromatographic separation was accomplished using a reversed phase C 18 Hichrom (250×4.6 mm, 5 m) column with the mobile phase consisting of acetonitrile-phosphate buffer (pH 3.2±0.1; 20 mM) (21:79, v/v) at a flow rate of 1 mL/min. Both intra- and inter day assay precision and accuracy were lower than 15% CV. The lower limit of quantitation was 25 ng/mL for lacosamide and the response was linear in a concentration range from 25 to 10 000 ng/mL. The developed method was successfully used for the preclinical pharmacokinetic study of lacosamide in rats.
| Original language | English |
|---|---|
| Pages (from-to) | 243-246 |
| Number of pages | 4 |
| Journal | Arzneimittel-Forschung/Drug Research |
| Volume | 62 |
| Issue number | 5 |
| DOIs | |
| Publication status | Published - 05-2012 |
All Science Journal Classification (ASJC) codes
- Drug Discovery
Fingerprint
Dive into the research topics of 'Development of a sensitive bioanalytical method for the quantification of lacosamide in rat plasmaapplication to preclinical pharmacokinetics studies in rats'. Together they form a unique fingerprint.Cite this