TY - JOUR
T1 - Does application of moderately concentrated platelet-rich plasma improve clinical and structural outcome after arthroscopic repair of medium-sized to large rotator cuff tear? A randomized controlled trial
AU - Pandey, Vivek
AU - Bandi, Atul
AU - Madi, Sandesh
AU - Agarwal, Lipisha
AU - Acharya, Kiran K.V.
AU - Maddukuri, Satish
AU - Sambhaji, Charudutt
AU - Willems, W. Jaap
PY - 2016/8/1
Y1 - 2016/8/1
N2 - Background: Platelet-rich plasma (PRP) has the potential to improve tendon-bone healing. The evidence is still controversial as to whether PRP application after repair of medium-sized to large cuff tears leads to superior structural and clinical outcome, especially after single-row repair. Methods: In a randomized study, 102 patients (PRP group, 52 patients; control group, 50 patients) with medium-sized and large degenerative posterosuperior tears were included for arthroscopic repair with a minimum follow-up of 2 years. Patients were evaluated with clinical scores (visual analog scale score, Constant-Murley score, University of California-Los Angeles score, and American Shoulder and Elbow Surgeons score) and ultrasound to assess retear and vascularity pattern of the cuff. Results: Visual analog scale scores were significantly lower in the PRP group than in controls at 1 month, 3 months, and 6 months but not later. Constant-Murley scores were significantly better in the PRP group compared with controls at 12 and 24 months, whereas University of California-Los Angeles scores were significantly higher in the PRP group at 6 and 12 months (P < .05). The American Shoulder and Elbow Surgeons score in both groups was comparable at all the times. At 24 months, retear in the PRP group (n = 2; 3.8%) was significantly lower than in the control group (n = 10; 20%; P = .01). The retear difference was significant only for large tears (PRP:control group, 1:6; P = .03). Doppler ultrasound examination showed significant vascularity in the PRP group repair site at 3 months postoperatively (P < .05) and in peribursal tissue until 12 months. Conclusion: Application of moderately concentrated PRP improves clinical and structural outcome in large cuff tears. PRP also enhances vascularity around the repair site in the early phase.
AB - Background: Platelet-rich plasma (PRP) has the potential to improve tendon-bone healing. The evidence is still controversial as to whether PRP application after repair of medium-sized to large cuff tears leads to superior structural and clinical outcome, especially after single-row repair. Methods: In a randomized study, 102 patients (PRP group, 52 patients; control group, 50 patients) with medium-sized and large degenerative posterosuperior tears were included for arthroscopic repair with a minimum follow-up of 2 years. Patients were evaluated with clinical scores (visual analog scale score, Constant-Murley score, University of California-Los Angeles score, and American Shoulder and Elbow Surgeons score) and ultrasound to assess retear and vascularity pattern of the cuff. Results: Visual analog scale scores were significantly lower in the PRP group than in controls at 1 month, 3 months, and 6 months but not later. Constant-Murley scores were significantly better in the PRP group compared with controls at 12 and 24 months, whereas University of California-Los Angeles scores were significantly higher in the PRP group at 6 and 12 months (P < .05). The American Shoulder and Elbow Surgeons score in both groups was comparable at all the times. At 24 months, retear in the PRP group (n = 2; 3.8%) was significantly lower than in the control group (n = 10; 20%; P = .01). The retear difference was significant only for large tears (PRP:control group, 1:6; P = .03). Doppler ultrasound examination showed significant vascularity in the PRP group repair site at 3 months postoperatively (P < .05) and in peribursal tissue until 12 months. Conclusion: Application of moderately concentrated PRP improves clinical and structural outcome in large cuff tears. PRP also enhances vascularity around the repair site in the early phase.
UR - http://www.scopus.com/inward/record.url?scp=84973882804&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84973882804&partnerID=8YFLogxK
U2 - 10.1016/j.jse.2016.01.036
DO - 10.1016/j.jse.2016.01.036
M3 - Article
C2 - 27262412
AN - SCOPUS:84973882804
SN - 1058-2746
JO - Journal of Shoulder and Elbow Surgery
JF - Journal of Shoulder and Elbow Surgery
ER -