TY - JOUR
T1 - Effect of comonomer of methacrylic acid on flexural strength and adhesion of Staphylococcus aureus to heat polymerized poly (methyl methacrylate) resin
T2 - An in vitro study
AU - Gupta, Lokendra
AU - Aparna, I. N.
AU - Bhat, Sujatha
AU - Ginjupalli, Kishore
PY - 2017/4/1
Y1 - 2017/4/1
N2 - Aims and Objective: The purpose of the present study was to evaluate and compare flexural strength and Staphylococcus aureus adhesion of heat-activated poly (methyl methacrylate [MMA]) resin modified with a comonomer of methacrylic acid (MAA) and MMA monomer. Materials and Methods: Comonomer preparation was done with the addition of varying concentration of MAA (0, 15, 20, and 25 wt %) to the MMA of conventional heat-activated denture base resin to prepare the specimens. Prepared specimens were stored in distilled water at 37°C for 1 day and 1 week before the evaluation of flexural strength and microbial adhesion. Flexural strength was measured using a universal testing machine at a crosshead speed for 2 mm/min (n = 10). Microbial adhesion (colony-forming unit [CFU]) was evaluated against S. aureus using a quadrant streaking method (n = 5). Data were subjected to one-way ANOVA, and the significant differences among the results were subjected to Tukey's HSD test. P < 0.05 was considered statistically significant. Results: Addition of MAA to the MMA monomer was found to significantly reduce the adhesion of S. aureus for all the groups. Reduction of CFU of S. aureus was found be more significant for Group 3 as compared to control, both at 1-day (P < 0.001) and 1-week (P < 0.002) storage in distilled water. However, no statistically significant changes in the flexural strength were observed with the addition of MAA at 1-day (P = 0.52) and 1-week (P = 0.88) time interval. Conclusion: Addition of MAA to conventional denture base resin reduced the microbial adhesion without significantly affecting the flexural strength.
AB - Aims and Objective: The purpose of the present study was to evaluate and compare flexural strength and Staphylococcus aureus adhesion of heat-activated poly (methyl methacrylate [MMA]) resin modified with a comonomer of methacrylic acid (MAA) and MMA monomer. Materials and Methods: Comonomer preparation was done with the addition of varying concentration of MAA (0, 15, 20, and 25 wt %) to the MMA of conventional heat-activated denture base resin to prepare the specimens. Prepared specimens were stored in distilled water at 37°C for 1 day and 1 week before the evaluation of flexural strength and microbial adhesion. Flexural strength was measured using a universal testing machine at a crosshead speed for 2 mm/min (n = 10). Microbial adhesion (colony-forming unit [CFU]) was evaluated against S. aureus using a quadrant streaking method (n = 5). Data were subjected to one-way ANOVA, and the significant differences among the results were subjected to Tukey's HSD test. P < 0.05 was considered statistically significant. Results: Addition of MAA to the MMA monomer was found to significantly reduce the adhesion of S. aureus for all the groups. Reduction of CFU of S. aureus was found be more significant for Group 3 as compared to control, both at 1-day (P < 0.001) and 1-week (P < 0.002) storage in distilled water. However, no statistically significant changes in the flexural strength were observed with the addition of MAA at 1-day (P = 0.52) and 1-week (P = 0.88) time interval. Conclusion: Addition of MAA to conventional denture base resin reduced the microbial adhesion without significantly affecting the flexural strength.
UR - http://www.scopus.com/inward/record.url?scp=85018891636&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85018891636&partnerID=8YFLogxK
U2 - 10.4103/jips.jips_257_16
DO - 10.4103/jips.jips_257_16
M3 - Article
AN - SCOPUS:85018891636
SN - 0972-4052
VL - 17
SP - 149
EP - 155
JO - Journal of Indian Prosthodontist Society
JF - Journal of Indian Prosthodontist Society
IS - 2
ER -