In-vivo Comparison of Planned and Measured Rectal Doses during Cobalt-60 HDR CT-based Intracavitary Brachytherapy Applications of Cervical Cancer Using the PTW 9112 Semiconductor Probe

Sunny K. Johan, Dilson Lobo, M. S. Athiyamaan, Challapalli Srinivas, Sourjya Banerjee, Krishna Abhishek, P. U.Prakash Saxena

Research output: Contribution to journalArticlepeer-review

Abstract

Background: A semiconductor rectal probe was used to compare planned and measured rectal doses during Co-60 high dose rate (HDR) CT-based intracavitary brachytherapy applications (ICBT) of cervical cancer. Materials and Methods: A total of 22 HDR brachytherapy applications were included from 11 patients who were first treated with EBRT to the whole pelvis with a total prescribed dose of 50 Gy in 25 fractions. During each application, a PTW 9112 probe rectal probe having a series of five semiconductor diodes (R1 to R5) was inserted into the patient’s rectum and a CT-based HDR ICBT application with a prescribed dose per fraction of 7 or 7.5 Gy to HRCTV was performed. Measurements were carried in water phantom using PTW rectal and universal adaptor plugs. Doses measured in phantom and with patients were compared to those calculated by the treatment planning system. Results: The mean percentage dose difference ΔD (%) between calculated and measured values from phantom study were -5.29%, 1.89%, -2.72%, -4.76, and 0.72% for R1, R2, R3, R4, and R3 diodes, respectively and the overall mean ΔD (%) value with standard deviation (SD) was -2.03%±9.6%. From the patient study, a ΔD (%) that ranged from -19.5% to 24.0%, which corresponded to dose disparities between -0.77 Gy and 0.66 Gy. The median ΔD (%) ranged from 0.4% to 1.3%, or -0.03 to 0.05 Gy, respectively. ΔD (%) values exceeded 10% in approximately 26.4% of measurements (29 out of 110 in 22 applications). The location of R max in computed and measured values differs in 5 of 22 applications might be due to possible displacement of rectal probe between simulation and treatment.

Original languageEnglish
Pages (from-to)897-907
Number of pages11
JournalAsian Pacific journal of cancer prevention : APJCP
Volume24
Issue number3
DOIs
Publication statusPublished - 01-03-2023

All Science Journal Classification (ASJC) codes

  • Epidemiology
  • Oncology
  • Public Health, Environmental and Occupational Health
  • Cancer Research

Fingerprint