TY - JOUR
T1 - LMA CTrach™ in patients with anticipated difficult airway
T2 - A retrospective study
AU - Krishna, H. M.
AU - Joseph, Nandhini
AU - Reddy, Pavani
AU - Dudeja, Yamini
PY - 2016
Y1 - 2016
N2 - LMA CTrach™, a newer airway conduit, with its ability to ventilate and intubate is the ideal device for airway management for difficult airways. A retrospective study was conducted to evaluate the efficacy of this airway device in patients with anticipated difficult airway. 250 patients in whom LMA CTrach™ was used for endotracheal intubation was analyzed. These patients were analyzed for anticipated difficult airway, success rate of intubation with LMA CTrach™, difficulties encountered and corrective measures applied. Fifty five patients had predictors of difficult airway and LMA CTrach™ was successful in all but one. Although successful intubation was achieved with LMA CTrach™, difficulty in intubation was encountered in six patients. This could be overcome with excessive pressure, correctional manoeuvers or a larger size LMA CTrach™. The most common predictors of difficult airway encountered were Modified Mallampati class 3, restricted extension, restricted mouth opening of two finger breadths and retrognathia. LMA CTrach™ is a useful airway device in a difficult airway scenario with the ability to ventilate and intubate the patient.
AB - LMA CTrach™, a newer airway conduit, with its ability to ventilate and intubate is the ideal device for airway management for difficult airways. A retrospective study was conducted to evaluate the efficacy of this airway device in patients with anticipated difficult airway. 250 patients in whom LMA CTrach™ was used for endotracheal intubation was analyzed. These patients were analyzed for anticipated difficult airway, success rate of intubation with LMA CTrach™, difficulties encountered and corrective measures applied. Fifty five patients had predictors of difficult airway and LMA CTrach™ was successful in all but one. Although successful intubation was achieved with LMA CTrach™, difficulty in intubation was encountered in six patients. This could be overcome with excessive pressure, correctional manoeuvers or a larger size LMA CTrach™. The most common predictors of difficult airway encountered were Modified Mallampati class 3, restricted extension, restricted mouth opening of two finger breadths and retrognathia. LMA CTrach™ is a useful airway device in a difficult airway scenario with the ability to ventilate and intubate the patient.
UR - http://www.scopus.com/inward/record.url?scp=84957864761&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84957864761&partnerID=8YFLogxK
U2 - 10.4038/slja.v24i1.8093
DO - 10.4038/slja.v24i1.8093
M3 - Article
AN - SCOPUS:84957864761
SN - 1391-8834
VL - 24
SP - 11
EP - 15
JO - Sri Lankan Journal of Anaesthesiology
JF - Sri Lankan Journal of Anaesthesiology
IS - 1
ER -