T1 - Modelling and analysis of polymer diaphragms for micro sensing and actuation
AU - Sushmita,
AU - Hiremath, Shivashankar
AU - Kulkarni, Satyabodh M.
N1 - Publisher Copyright:
© 2019 Author(s).
PY - 2019/3/8
Y1 - 2019/3/8
N2 - Micro sensors and actuators have potential applications in the domains like biomedical, energy harvesting and MEMS. The thin diaphragm as a primary micromechanical element is commonly seen in most of these systems. In recent days polymer-based diaphragms are being used instead of metallic diaphragms as they are more compliant, biocompatible and economical to process. Among polymers, Polydimethylsiloxane (PDMS) is by far the most widely used polymer. Fabrication and prototyping of microfluidic chips is a major area where PDMS is used. PDMS being bio-stable is used for biomedical applications such as drug delivery system and blood-contacting biomaterials. In the present work, the analysis is performed to investigate the behavior of PDMS films along with Parylene and Polyimide films. The deflection of the polymer diaphragms is computed using the analytical and finite element (FE) approaches. The deflection is computed considering the edges of the diaphragm to be fixed and the diaphragm subjected to uniform pressure. Three geometries (Circle, Rectangle, and Square) and three thicknesses are considered for each of the above materials. The results of the FE model and analytical computation are found to be in good agreement with each other. It is observed that the PDMS diaphragms with circular geometry exhibited larger deflection. The deflection values appear to be suitable for enhancing diaphragm performance in applications like micro pumps and energy harvesting devices.
AB - Micro sensors and actuators have potential applications in the domains like biomedical, energy harvesting and MEMS. The thin diaphragm as a primary micromechanical element is commonly seen in most of these systems. In recent days polymer-based diaphragms are being used instead of metallic diaphragms as they are more compliant, biocompatible and economical to process. Among polymers, Polydimethylsiloxane (PDMS) is by far the most widely used polymer. Fabrication and prototyping of microfluidic chips is a major area where PDMS is used. PDMS being bio-stable is used for biomedical applications such as drug delivery system and blood-contacting biomaterials. In the present work, the analysis is performed to investigate the behavior of PDMS films along with Parylene and Polyimide films. The deflection of the polymer diaphragms is computed using the analytical and finite element (FE) approaches. The deflection is computed considering the edges of the diaphragm to be fixed and the diaphragm subjected to uniform pressure. Three geometries (Circle, Rectangle, and Square) and three thicknesses are considered for each of the above materials. The results of the FE model and analytical computation are found to be in good agreement with each other. It is observed that the PDMS diaphragms with circular geometry exhibited larger deflection. The deflection values appear to be suitable for enhancing diaphragm performance in applications like micro pumps and energy harvesting devices.
UR - http://www.scopus.com/inward/record.url?scp=85063297110&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85063297110&partnerID=8YFLogxK
U2 - 10.1063/1.5092887
DO - 10.1063/1.5092887
M3 - Conference contribution
AN - SCOPUS:85063297110
T3 - AIP Conference Proceedings
BT - Emerging Trends in Mechanical Engineering 2018
A2 - Gopalakrishna, Binu K.
A2 - Mudradi, Sudheer
PB - American Institute of Physics Inc.
T2 - International Conference on Emerging Trends in Mechanical Engineering 2018, eTIME-2018
Y2 - 10 August 2018 through 11 August 2018
ER -