N2 - Objectives: In gas turbine blades, heat transmission can be improved by using twisted tape inserts. In the present paper, cooling effect of a gas turbine blade can be improved by using suitable twisted tape configurations. Methods/Statistical Analysis: It was found from validation test that the twisted tape is a favourable technique for heat transfer augmentation. It was also found that heat transfer can be enhanced in the cases with suitable width ratio of twisted tapes. CFD Results show that the results are satisfactory when compared with the reference journal paper. Simulations are carried out for different width ratios of twisted tape inserts. Findings: Computation results showed that by employing twisted tape inserts of width ratio (W) = 0.3 provides better cooling effect compared to the others. The blade temperature is decreased by 34% at the leading edge. Application/Improvements: All these established that influence of cooling over gas turbine blade particularly at the leading edge can be enhanced with suitable twisted tape insert configurations.
AB - Objectives: In gas turbine blades, heat transmission can be improved by using twisted tape inserts. In the present paper, cooling effect of a gas turbine blade can be improved by using suitable twisted tape configurations. Methods/Statistical Analysis: It was found from validation test that the twisted tape is a favourable technique for heat transfer augmentation. It was also found that heat transfer can be enhanced in the cases with suitable width ratio of twisted tapes. CFD Results show that the results are satisfactory when compared with the reference journal paper. Simulations are carried out for different width ratios of twisted tape inserts. Findings: Computation results showed that by employing twisted tape inserts of width ratio (W) = 0.3 provides better cooling effect compared to the others. The blade temperature is decreased by 34% at the leading edge. Application/Improvements: All these established that influence of cooling over gas turbine blade particularly at the leading edge can be enhanced with suitable twisted tape insert configurations.
UR - http://www.scopus.com/inward/record.url?scp=84984853614&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84984853614&partnerID=8YFLogxK
U2 - 10.17485/ijst/2016/v9i31/95795
DO - 10.17485/ijst/2016/v9i31/95795
M3 - Article
AN - SCOPUS:84984853614
SN - 0974-6846
VL - 9
JO - Indian Journal of Science and Technology
JF - Indian Journal of Science and Technology
IS - 31
M1 - 95795
ER -