Droplet microfluidics finds its application in medical, chemical and biological research as well as in the field of medical device manufacturing. This paper studies the T-junction microfluidics and its parameters, such as droplet length and breakup time, as they vary with the channel width and phase velocities. The study reveals that droplet length rises with an increase in either of the channel width and time taken for breakup reduces and attains a steady value when dispersed phase width is increased. The droplets are smaller in size and form very quickly when the velocity of continuous phase is increased and vice versa. The study can be utilized as a part of a larger study of droplets and their particle encapsulations, and its utilization to generate more efficient and economical medical devices.

Original languageEnglish
Pages (from-to)168-178
Number of pages11
JournalJournal of Applied Engineering Science
Volume24
Issue number1
DOIs
Publication statusPublished - 02-03-2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

All Science Journal Classification (ASJC) codes

  • Civil and Structural Engineering
  • Renewable Energy, Sustainability and the Environment
  • Transportation
  • Safety, Risk, Reliability and Quality
  • General Engineering
  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'NUMERICAL STUDY OF DROPLET LENGTH AND BREAKUP TIME FOR GEOMETRY AND FLOW PARAMETERS IN A T-JUNCTION MICROFLUIDICS'. Together they form a unique fingerprint.

Cite this