TY - JOUR
T1 - Pneumatic impression
T2 - Improving dental arch impression with an inflatable balloon
AU - Gupta, Lokendra
N1 - Publisher Copyright:
© 2016 The Journal of Indian Prosthodontic Society.
PY - 2016/7/1
Y1 - 2016/7/1
N2 - Purpose: The purpose of this impression technique is to overcome the problem associated with restricted mouth opening in association with high arched palate by employing pneumatic impression technique using latex balloon. Methods: A stock tray was modified with auto polymerizing acrylic resin. On the modified tray, a latex balloon was attached with aid of cyanoacrylate. The outlet of the balloon was then connected to a clinical sphygmomanometer bulb with the rubber pipe for air passage which would aid in inflating the balloon. The prepared tray assembly was then equipped for recording the impression. An adequate amount of addition polysiloxane impression material, sufficient to cover the entire area of the balloon was loaded onto the tray. The balloon was then inflated with the help of a sphygmomanometer bulb which transferred the air only in one direction. On completion of setting time of the impression material, the air pressure was relieved by deflating of balloon which helped in the easy removal of the impression. The impression was subsequently removed from the oral cavity and disinfected. Conclusion: This novel technique was helpful for recording impression in patients presenting with restricted mouth opening and high arched palate.
AB - Purpose: The purpose of this impression technique is to overcome the problem associated with restricted mouth opening in association with high arched palate by employing pneumatic impression technique using latex balloon. Methods: A stock tray was modified with auto polymerizing acrylic resin. On the modified tray, a latex balloon was attached with aid of cyanoacrylate. The outlet of the balloon was then connected to a clinical sphygmomanometer bulb with the rubber pipe for air passage which would aid in inflating the balloon. The prepared tray assembly was then equipped for recording the impression. An adequate amount of addition polysiloxane impression material, sufficient to cover the entire area of the balloon was loaded onto the tray. The balloon was then inflated with the help of a sphygmomanometer bulb which transferred the air only in one direction. On completion of setting time of the impression material, the air pressure was relieved by deflating of balloon which helped in the easy removal of the impression. The impression was subsequently removed from the oral cavity and disinfected. Conclusion: This novel technique was helpful for recording impression in patients presenting with restricted mouth opening and high arched palate.
UR - https://www.scopus.com/pages/publications/84979913344
UR - https://www.scopus.com/pages/publications/84979913344#tab=citedBy
U2 - 10.4103/0972-4052.186401
DO - 10.4103/0972-4052.186401
M3 - Article
AN - SCOPUS:84979913344
SN - 0972-4052
VL - 16
SP - 311
EP - 314
JO - Journal of Indian Prosthodontist Society
JF - Journal of Indian Prosthodontist Society
IS - 3
ER -