Skip to main navigation Skip to search Skip to main content

PSA detection using label free graphene FET with coplanar electrodes based microfluidic point of care diagnostic device

  • Naresh Mandal
  • , Victor Pakira
  • , Nirmalya Samanta
  • , Naren Das
  • , Suman Chakraborty
  • , Bidhan Pramanick
  • , Chirasree RoyChaudhuri*
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Affordable point-of-care (PoC) diagnostic devices enable detection of prostate specific antigen (PSA) in resource limited settings. Despite the advancements in PoC systems, most of the reported methods for PSA detection have unsatisfactory detection limits and are based on labelled assays, requiring multiple reagent flow steps which increases both expenses and inconvenience. Circumventing these constraints, we report here the development and validation of a label free, affordable dielectrophoresis (DEP) based graphene field effect transistor (FET) sensor implemented using coplanar electrodes and integrated uniquely with a compact disc based microfluidic platform along with electronics readout for the estimation of PSA at the point of care. Design of coplanar gate electrode which has not been explored earlier is not a straightforward approach. In fact, it has been observed that there is a non-monotonic dependence of the capture of PSA molecules in the channel region of the FET with varying widths and spacings of the gate electrode. The graphene FET based PoC device with optimized coplanar gate electrode is the only label free analytical system for PSA detection requiring simple operation and achieving a detection limit of 1 pg/ml in serum with a wide dynamic range upto 4 ng/ml and appreciable selectivity against potential interferents like bovine serum albumin (BSA) and human immunoglobulin G (IgG). Further, it has been validated satisfactorily with commercially available existing systems using human serum samples. Moreover, the proposed sensing system lowers the detection limit by three orders of magnitude compared to a recent study on label free PoC device on other cancer biomarkers.

Original languageEnglish
Article number121581
JournalTalanta
Volume222
DOIs
Publication statusPublished - 15-01-2021

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

Fingerprint

Dive into the research topics of 'PSA detection using label free graphene FET with coplanar electrodes based microfluidic point of care diagnostic device'. Together they form a unique fingerprint.

Cite this