TY - JOUR
T1 - Real eyes realizes real lies
T2 - A case report and review of nuisance antibodies in immunohematology
AU - Kandasamy, Dhivya
AU - Shastry, Shamee
AU - Chenna, Deepika
AU - Mohan, Ganesh
N1 - Publisher Copyright:
© 2018 Asian Journal of Transfusion Science | Published by Wolters Kluwer-Medknow.
PY - 2018/7/1
Y1 - 2018/7/1
N2 - Detection of nonspecific antibodies unrelated to blood group antigen that causes nuisance in pretransfusion testing is a rare event. Their interpretation is often made only after the exclusion of all possible clinically significant antibodies and results in the unnecessary expenditure of reagents and human resources. We report one such nuisance antibody detected in an antenatal female that showed pan reaction with antibody screening and identification panel red cells including auto control but was compatible with group-specific donor units. Direct antiglobulin test was positive with no hematological evidence of bleeding. Repeat antibody screening test performed after washing the panel red cells and use of panel cells from different manufacturer showed negative reaction raising the suspicion of antibody specificity against chemical constituents in suspension medium of panel cells. Interpretation of nonspecific antibodies as to what they really are demands extensive immunohematological work-up and causes a delay in issue of blood components to the recipient.
AB - Detection of nonspecific antibodies unrelated to blood group antigen that causes nuisance in pretransfusion testing is a rare event. Their interpretation is often made only after the exclusion of all possible clinically significant antibodies and results in the unnecessary expenditure of reagents and human resources. We report one such nuisance antibody detected in an antenatal female that showed pan reaction with antibody screening and identification panel red cells including auto control but was compatible with group-specific donor units. Direct antiglobulin test was positive with no hematological evidence of bleeding. Repeat antibody screening test performed after washing the panel red cells and use of panel cells from different manufacturer showed negative reaction raising the suspicion of antibody specificity against chemical constituents in suspension medium of panel cells. Interpretation of nonspecific antibodies as to what they really are demands extensive immunohematological work-up and causes a delay in issue of blood components to the recipient.
UR - http://www.scopus.com/inward/record.url?scp=85059473812&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85059473812&partnerID=8YFLogxK
U2 - 10.4103/ajts.AJTS_100_17
DO - 10.4103/ajts.AJTS_100_17
M3 - Article
AN - SCOPUS:85059473812
SN - 0973-6247
VL - 12
SP - 169
EP - 172
JO - Asian Journal of Transfusion Science
JF - Asian Journal of Transfusion Science
IS - 2
ER -