T1 - Role of Shear Wave Elastography in the Assessment of Fibrosis in Chronic Liver Disease
AU - Bellamkonda, Sravya
AU - Paruthikunnan, Samir M.
AU - Kadavigere, Rajgopal V.
AU - Sripathi, Smiti
N1 - Publisher Copyright:
© The Author(s) 2018.
PY - 2018/11/1
Y1 - 2018/11/1
N2 - Objective: To evaluate the diagnostic performance of shear wave elastography in the estimation of fibrosis in patients with chronic liver disease by using biopsy and/or serum markers as reference standard. Materials and methods: 100 patients underwent point quantification-shear wave elastography, for whom noninvasive serum fibrosis indices like APRI, FIB-4, and King’s score were calculated. The receiver-operator characteristic (ROC) curve analysis was performed. Results: The shear wave elastography measurements showed moderate agreement with APRI, FIB-4, and fair agreement with King’s score. The AUROC for differentiating F0-F1, F2-F3, F2-F3, and F4 are 0.873 and 0.504 respectively using APRI as reference standard. The cutoff values derived for differentiating F0-F1 and F2-F3 was 7.07 and for differentiating F2-F3 and F4 was 11.94. Conclusion: The diagnostic performance of shear wave elastography is comparable with that of serum fibrosis indices APRI and FIB-4.
AB - Objective: To evaluate the diagnostic performance of shear wave elastography in the estimation of fibrosis in patients with chronic liver disease by using biopsy and/or serum markers as reference standard. Materials and methods: 100 patients underwent point quantification-shear wave elastography, for whom noninvasive serum fibrosis indices like APRI, FIB-4, and King’s score were calculated. The receiver-operator characteristic (ROC) curve analysis was performed. Results: The shear wave elastography measurements showed moderate agreement with APRI, FIB-4, and fair agreement with King’s score. The AUROC for differentiating F0-F1, F2-F3, F2-F3, and F4 are 0.873 and 0.504 respectively using APRI as reference standard. The cutoff values derived for differentiating F0-F1 and F2-F3 was 7.07 and for differentiating F2-F3 and F4 was 11.94. Conclusion: The diagnostic performance of shear wave elastography is comparable with that of serum fibrosis indices APRI and FIB-4.
UR - https://www.scopus.com/pages/publications/85056718032
UR - https://www.scopus.com/inward/citedby.url?scp=85056718032&partnerID=8YFLogxK
U2 - 10.1177/8756479318799340
DO - 10.1177/8756479318799340
M3 - Article
AN - SCOPUS:85056718032
SN - 8756-4793
VL - 34
SP - 460
EP - 465
JO - Journal of Diagnostic Medical Sonography
JF - Journal of Diagnostic Medical Sonography
IS - 6
ER -