T1 - Serial blood volume estimation in rabbits using trivalent chromium – An exploratory study
AU - Baby, Prathap Moothamadathil
AU - Kumar, Pramod
AU - Kumar, Rajesh
AU - Jacob, Sanu Susan
AU - Rawat, Dinesh
AU - VS, Binu
AU - Karun, Kalesh M.
AU - Bhat, Nishanth B.
N1 - Publisher Copyright:
© 2019 The Authors
PY - 2019/1/1
Y1 - 2019/1/1
N2 - Though often used in cardiac intensive monitoring set up, simultaneous evaluation of several variables like CVP, PCWP, SVV and hTEE for fluid volume resuscitation (especially when capillary permeability is major problem than cardiac performance)is a major challenge in many ICU setups. Therefore, repetitive determination of blood volume by trivalent chromium [51Cr (III)]as a direct single variable method may be a near ideal method during fluid volume resuscitation in cases where capillary permeability is a major problem (e.g. Burns). Hence, in the present article the repeatability and reliability of 51Cr (III)method in New Zealand white rabbits was explored. Mean blood volume values of initial measurement were 195.66 ± 47.30 ml or 89.81 ± 17.88 ml/kg body weight. Repeated mean blood volume values, measured after 1 h, was 181.98 ± 53.16 ml or 83.68 ± 22.09 ml/kg body weight. The average difference between the initial and repeated measurements was 10.93 ml (95% CI −3.33, 25.19 ml), which is not statistically significant (P = 0.128). The method using 51Cr (III)for repeat blood volume measurements after sixty minutes in rabbits is a reliable method. • Rapid • Repeatable • Reliable
AB - Though often used in cardiac intensive monitoring set up, simultaneous evaluation of several variables like CVP, PCWP, SVV and hTEE for fluid volume resuscitation (especially when capillary permeability is major problem than cardiac performance)is a major challenge in many ICU setups. Therefore, repetitive determination of blood volume by trivalent chromium [51Cr (III)]as a direct single variable method may be a near ideal method during fluid volume resuscitation in cases where capillary permeability is a major problem (e.g. Burns). Hence, in the present article the repeatability and reliability of 51Cr (III)method in New Zealand white rabbits was explored. Mean blood volume values of initial measurement were 195.66 ± 47.30 ml or 89.81 ± 17.88 ml/kg body weight. Repeated mean blood volume values, measured after 1 h, was 181.98 ± 53.16 ml or 83.68 ± 22.09 ml/kg body weight. The average difference between the initial and repeated measurements was 10.93 ml (95% CI −3.33, 25.19 ml), which is not statistically significant (P = 0.128). The method using 51Cr (III)for repeat blood volume measurements after sixty minutes in rabbits is a reliable method. • Rapid • Repeatable • Reliable
UR - http://www.scopus.com/inward/record.url?scp=85065566646&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85065566646&partnerID=8YFLogxK
U2 - 10.1016/j.mex.2019.05.009
DO - 10.1016/j.mex.2019.05.009
M3 - Article
AN - SCOPUS:85065566646
SN - 2215-0161
VL - 6
SP - 1068
EP - 1071
JO - MethodsX
JF - MethodsX
ER -