TY - JOUR
T1 - Surveillance of influenza A and B viruses from community and hospital wastewater treatment plants
AU - Panneerselvam, Sneka
AU - Manayan Parambil, Athira
AU - Jayaram, Anup
AU - Varamballi, Prasad
AU - Mukhopadhyay, Chiranjay
AU - Jagadesh, Anitha
N1 - Publisher Copyright:
© 2024 The Author(s). Environmental Microbiology Reports published by John Wiley & Sons Ltd.
PY - 2024/8
Y1 - 2024/8
N2 - Influenza virus is a well-known pathogen that can cause epidemics and pandemics. Several surveillance methods are being followed to monitor the transmission patterns and spread of influenza in the community. Wastewater-based Epidemiology (WBE) can serve as an additional tool to detect the presence of influenza viruses. The current study primarily focuses on surveillance of Influenza A and Influenza B in wastewater treatment plant (WWTP) samples. A total of 100 wastewater samples were collected in July (n = 50) and August (n = 50) 2023 from four different WWTPs in Manipal and Udupi, district of Karnataka, India. The WWTP samples were processed and tested by Real-Time reverse transcriptase PCR (RT-PCR). The data generated was analysed in comparison with the clinical Influenza cases. Of the 100 samples, 18 (18%) tested positive for Influenza A virus and 2 (2%) tested positive for Influenza B virus, with a viral load ranging 1.4 x 102–2.2 x 103 gc/L for influenza A virus and 5.2 x 103–7.7 x 103gc/L for influenza B virus. On correlating the WWTP positivity with clinical case, it was found that influenza clinical cases and virus positivity in wastewater increased simultaneously, emphasizing WBE as a concurrent method for monitoring influenza virus activity.
AB - Influenza virus is a well-known pathogen that can cause epidemics and pandemics. Several surveillance methods are being followed to monitor the transmission patterns and spread of influenza in the community. Wastewater-based Epidemiology (WBE) can serve as an additional tool to detect the presence of influenza viruses. The current study primarily focuses on surveillance of Influenza A and Influenza B in wastewater treatment plant (WWTP) samples. A total of 100 wastewater samples were collected in July (n = 50) and August (n = 50) 2023 from four different WWTPs in Manipal and Udupi, district of Karnataka, India. The WWTP samples were processed and tested by Real-Time reverse transcriptase PCR (RT-PCR). The data generated was analysed in comparison with the clinical Influenza cases. Of the 100 samples, 18 (18%) tested positive for Influenza A virus and 2 (2%) tested positive for Influenza B virus, with a viral load ranging 1.4 x 102–2.2 x 103 gc/L for influenza A virus and 5.2 x 103–7.7 x 103gc/L for influenza B virus. On correlating the WWTP positivity with clinical case, it was found that influenza clinical cases and virus positivity in wastewater increased simultaneously, emphasizing WBE as a concurrent method for monitoring influenza virus activity.
UR - http://www.scopus.com/inward/record.url?scp=85201684660&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85201684660&partnerID=8YFLogxK
U2 - 10.1111/1758-2229.13317
DO - 10.1111/1758-2229.13317
M3 - Article
C2 - 39171887
AN - SCOPUS:85201684660
SN - 1758-2229
VL - 16
JO - Environmental Microbiology Reports
JF - Environmental Microbiology Reports
IS - 4
M1 - e13317
ER -