T1 - Test-Retest Reliability of the Win-Track Platform in Analyzing the Gait Parameters and Plantar Pressures During Barefoot Walking in Healthy Adults
AU - Ramachandra, Preetha
AU - Maiya, Arun G.
AU - Kumar, Pratap
PY - 2012/10/1
Y1 - 2012/10/1
N2 - The Win-Track platform is an instrument used to measure plantar pressures and gait parameters during barefoot walking. The objective of this study was to determine the test-retest reliability of the system in assessing plantar pressures and temporal gait variables between 1-step and 3-step gait protocols. A total of 30 healthy participants (18 women and 12 men; age 23.7 ± 4.75 years) were recruited for the study. The 1-step gait protocol exhibited good reliability in terms of single stance, step duration and swing duration of the left foot; stride duration of the right foot; stride length; and step length of the right foot, with intraclass correlation coefficients (ICCs) ranging from 0.75 to 0.88. The 3-step gait protocol showed good reliability, with ICC values ranging between 0.75 and 0.90 in cadence; step duration of the right foot; double-stance duration and swing duration of the right foot; stride length of the right foot; step length and gait cycle length of the right and the left foot; and the area covered by the first, second, and third foot. The authors concluded that the Win-Track platform provided reliable plantar pressures and temporal gait measures, and the 3-step gait protocol showed better reliability compared with the 1-step gait protocol.Level of Evidence: Diagnostic, Level IV.
AB - The Win-Track platform is an instrument used to measure plantar pressures and gait parameters during barefoot walking. The objective of this study was to determine the test-retest reliability of the system in assessing plantar pressures and temporal gait variables between 1-step and 3-step gait protocols. A total of 30 healthy participants (18 women and 12 men; age 23.7 ± 4.75 years) were recruited for the study. The 1-step gait protocol exhibited good reliability in terms of single stance, step duration and swing duration of the left foot; stride duration of the right foot; stride length; and step length of the right foot, with intraclass correlation coefficients (ICCs) ranging from 0.75 to 0.88. The 3-step gait protocol showed good reliability, with ICC values ranging between 0.75 and 0.90 in cadence; step duration of the right foot; double-stance duration and swing duration of the right foot; stride length of the right foot; step length and gait cycle length of the right and the left foot; and the area covered by the first, second, and third foot. The authors concluded that the Win-Track platform provided reliable plantar pressures and temporal gait measures, and the 3-step gait protocol showed better reliability compared with the 1-step gait protocol.Level of Evidence: Diagnostic, Level IV.
UR - http://www.scopus.com/inward/record.url?scp=84866710408&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84866710408&partnerID=8YFLogxK
U2 - 10.1177/1938640012457680
DO - 10.1177/1938640012457680
M3 - Article
C2 - 22956663
AN - SCOPUS:84866710408
SN - 1938-6400
VL - 5
SP - 306
EP - 312
JO - Foot and Ankle Specialist
JF - Foot and Ankle Specialist
IS - 5
ER -