TY - JOUR
T1 - The crossed-leg position increases the dimensions within the acoustic target window for neuraxial needle placement in term pregnancy
T2 - a prospective observational study: The crossed-leg position and the acoustic target window for neuraxial needle placement
AU - Sharma, M.
AU - Qasem, F.
AU - Sebbag, I.
AU - Jones, P. M.
AU - Singh, S. I.
PY - 2020/11
Y1 - 2020/11
N2 - Introduction: Neuraxial anesthesia in obstetric patients may be difficult to achieve due to anatomical changes in pregnancy. The crossed-leg position may help in optimizing patient position. We prospectively evaluated the utility of the crossed-leg position compared with a standard position using ultrasound measurements. Methods: Thirty women with term singleton pregnancy admitted for vaginal delivery were recruited. Women with a history of spinal trauma or surgery, congenital spinal abnormality, advanced first stage of labor or a language barrier were excluded. Two anesthesiologists, blinded to each other's measurements, scanned each subject in the crossed-leg position and standard position. Measurements of the lengths of the posterior longitudinal ligament, ligamentum flavum and interlaminar distance were recorded at the L3-L4 interspace. Comfort level in each position was scored on a Likert Scale. Results: Twenty-nine women completed the study (complete data n=28). Significant increases were observed in the lengths of the posterior longitudinal ligament (mean difference 2.2 mm, 95% CI 1.3 to 3.2; P <0.001), ligamentum flavum (mean difference 1.4 mm, 95% CI 0.7 to 2.1; P <0.001) and interlaminar distance (mean difference 1.4 mm, 95% CI 0.4 to 2.5; P=0.006) in the crossed-leg position. No significant differences in comfort were observed. Conclusion: We demonstrated a statistically significant increase in the sonographically measured lengths of the posterior longitudinal ligament, ligamentum flavum and interlaminar distance in the crossed-leg position when compared with to the standard position. Both positions were comfortable. Further studies should explore whether these findings translate clinically into easier needle placement in the crossed-leg position.
AB - Introduction: Neuraxial anesthesia in obstetric patients may be difficult to achieve due to anatomical changes in pregnancy. The crossed-leg position may help in optimizing patient position. We prospectively evaluated the utility of the crossed-leg position compared with a standard position using ultrasound measurements. Methods: Thirty women with term singleton pregnancy admitted for vaginal delivery were recruited. Women with a history of spinal trauma or surgery, congenital spinal abnormality, advanced first stage of labor or a language barrier were excluded. Two anesthesiologists, blinded to each other's measurements, scanned each subject in the crossed-leg position and standard position. Measurements of the lengths of the posterior longitudinal ligament, ligamentum flavum and interlaminar distance were recorded at the L3-L4 interspace. Comfort level in each position was scored on a Likert Scale. Results: Twenty-nine women completed the study (complete data n=28). Significant increases were observed in the lengths of the posterior longitudinal ligament (mean difference 2.2 mm, 95% CI 1.3 to 3.2; P <0.001), ligamentum flavum (mean difference 1.4 mm, 95% CI 0.7 to 2.1; P <0.001) and interlaminar distance (mean difference 1.4 mm, 95% CI 0.4 to 2.5; P=0.006) in the crossed-leg position. No significant differences in comfort were observed. Conclusion: We demonstrated a statistically significant increase in the sonographically measured lengths of the posterior longitudinal ligament, ligamentum flavum and interlaminar distance in the crossed-leg position when compared with to the standard position. Both positions were comfortable. Further studies should explore whether these findings translate clinically into easier needle placement in the crossed-leg position.
UR - http://www.scopus.com/inward/record.url?scp=85090825546&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85090825546&partnerID=8YFLogxK
U2 - 10.1016/j.ijoa.2020.08.011
DO - 10.1016/j.ijoa.2020.08.011
M3 - Article
C2 - 32942215
AN - SCOPUS:85090825546
SN - 0959-289X
VL - 44
SP - 106
EP - 111
JO - International Journal of Obstetric Anesthesia
JF - International Journal of Obstetric Anesthesia
ER -