TY - JOUR
T1 - The efficacy of different irrigation protocols in removing tricalcium silicate-based sealers from simulated root canal irregularities
AU - Ballal, Nidambur Vasudev
AU - Ulusoy, Özgür İlke
AU - Rao, Sheetal
AU - Gandhi, Poornika
PY - 2019/11/1
Y1 - 2019/11/1
N2 - Objective: The aim of this study was to evaluate the efficacy of different irrigation protocols in removing two tricalcium silicate-based sealers from simulated root canal irregularities and root canal walls. Material and methods: Root canals of 140 single-rooted teeth were instrumented. In one-half of each root, an apical groove was created. The samples were divided into two main groups (n = 70) based on the sealer used. In group 1, the grooves were filled with MTA Fillapex; in group 2, BioRoot RCS. The reassembled root halves were divided into six experimental and one control groups: 2.5% NaOCl-17% EDTA (Passive ultrasonic irrigation [PUI]), 5% NaOCl/9% DualRinse HEDP (PUI), 2.5% NaOCl-7% Maleic acid (PUI), 2.5% NaOCl-17% EDTA (Er:YAG laser activated irrigation [LAI]), 2.5% NaOCl/9% DualRinse HEDP (LAI), 2.5% NaOCl-7% Maleic acid (LAI), Distilled water (Control). Specimens were scored using SEM. The data were analysed using Kruskal-Wallis and Mann Whitney U tests. Results: Maleic acid and DualRinse HEDP removed higher amounts of MTA Fillapex from the grooves compared to EDTA, when used with both activation methods (p <.001). Conclusions: Ultrasonically activated maleic acid or DualRinse HEDP can be an effective irrigation regimen in removing tricalcium silicate-based sealers.
AB - Objective: The aim of this study was to evaluate the efficacy of different irrigation protocols in removing two tricalcium silicate-based sealers from simulated root canal irregularities and root canal walls. Material and methods: Root canals of 140 single-rooted teeth were instrumented. In one-half of each root, an apical groove was created. The samples were divided into two main groups (n = 70) based on the sealer used. In group 1, the grooves were filled with MTA Fillapex; in group 2, BioRoot RCS. The reassembled root halves were divided into six experimental and one control groups: 2.5% NaOCl-17% EDTA (Passive ultrasonic irrigation [PUI]), 5% NaOCl/9% DualRinse HEDP (PUI), 2.5% NaOCl-7% Maleic acid (PUI), 2.5% NaOCl-17% EDTA (Er:YAG laser activated irrigation [LAI]), 2.5% NaOCl/9% DualRinse HEDP (LAI), 2.5% NaOCl-7% Maleic acid (LAI), Distilled water (Control). Specimens were scored using SEM. The data were analysed using Kruskal-Wallis and Mann Whitney U tests. Results: Maleic acid and DualRinse HEDP removed higher amounts of MTA Fillapex from the grooves compared to EDTA, when used with both activation methods (p <.001). Conclusions: Ultrasonically activated maleic acid or DualRinse HEDP can be an effective irrigation regimen in removing tricalcium silicate-based sealers.
UR - http://www.scopus.com/inward/record.url?scp=85070056740&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85070056740&partnerID=8YFLogxK
U2 - 10.1002/jemt.23353
DO - 10.1002/jemt.23353
M3 - Article
C2 - 31368166
AN - SCOPUS:85070056740
SN - 1059-910X
VL - 82
SP - 1862
EP - 1868
JO - Microscopy Research and Technique
JF - Microscopy Research and Technique
IS - 11
ER -